Research Library
Discover insights from thousands of peer-reviewed papers on microbial electrochemical systems
Discover insights from thousands of peer-reviewed papers on microbial electrochemical systems
• 2009
• 2007
Preface. 1. Introduction. 1.1. Energy needs. 1.2. Energy and the challenge of global climate change. 1.3. Bioelectricity generation using a microbial fuel cell --the process of electrogenesis. 1.4. MFCs and energy sustainability of the water infrastructure. 1.5. MFC technologies for wastewater treatment. 1.6. Renewable energy generation using MFCs. 1.7. Other applications of MFC technologies. 2. Exoelectrogens. 2.1. Introduction. 2.2. Mechanisms of electron transfer. 2.3. MFC studies using known exoelectrogenic strains. 2.4. Community analysis. 2.5. MFCs as tools for studying exoelectrogens. 3. Voltage generation. 3.1. Voltage and current. 3.2. Maximum voltages based on thermodynamic relationships. 3.3. Anode potentials and enzyme potentials. 3.4. Role of enzymes versus communities in setting anode potentials. 3.5. Voltage generation by fermentative bacteria? 4. Power generation. 4.1. Calculating power. 4.2. Coulombic and energy efficiency. 4.3. Polarization and power density curves. 4.4. Measuring internal resistance. 4.5. Chemical and electrochemical analysis of reactors. 5. Materials. 5.1. Finding low-cost, highly efficient materials. 5.2. Anode materials. 5.3. Membranes and separators (and chemical transport through them). 5.4. Cathode materials. 5.5. Long term stability of different materials. 6. Architecture. 6.1. General requirements. 6.2. Air-cathode MFCs. 6.3. Aqueous cathodes using dissolved oxygen. 6.4. Two chamber reactors with soluble catholytes or poised potentials. 6.5. Tubular packed bed reactors. 6.6. Stacked MFCs. 6.7. Metal catholytes. 6.8. Biohydrogen MFCs. 6.9. Towards a scaleable MFC architecture. 7. Kinetics and Mass transfer. 7.1. Kinetic or mass transfer models? 7.2. Boundaries on rate constants and bacterial characteristics. 7.3. Maximum power from a monolayer of bacteria. 7.4. Maximum rate of mass transfer to a biofilm. 7.5. Mass transfer per reactor volume. 8. MECs for hydrogen production. 8.1. Principle of operation. 8.2. MEC systems. 8.3. Hydrogen yields. 8.4. Hydrogen recovery. 8.5. Energy recovery. 8.6. Hydrogen losses. 8.7. Differences between the MEC and MFC systems. 9. MFCs for Wastewater Treatment. 9.1. Process trains for WWTPs. 9.2. Replacement of the biological treatment reactor with an MFC. 9.3. Energy balances for WWTPs. 9.4. Implications for reduced sludge generation. 9.5. Nutrient removal. 9.6. Electrogenesis versus methanogensis. 10. Other MFC Technologies. 10.1. Different applications for MFC-based technologies. 10.2. Sediment MFCs. 10.3. Enhanced sediment MFCs. 10.4. Bioremediation using MFC technologies. 11. Fun! 11.1 MFCs for new scientists and inventors. 11.2 Choosing your inoculum and media. 11.3 MFC materials: electrodes and membranes. 11.4 MFC architectures that are easy to build. 11.5 MFC reactors 11.6 Operation and assessment of MFCs. 12. Outlook. 12.1 MFCs yesterday and today. 12.2 Challenges for bringing MFCs to commercialization. 12.3 Accomplishments and outlook. Notation. References. Index.
• 2011
• 2020
The proof-of-principle of metal recovery by using the microbial electrochemical snorkel (MES) is provided for the first time. Copper electrodes were short-circuited with the bioanodes of sediment microbial fuel cells (MFC). Two MES setups with and without separation of the compartments by proton exchange membrane (PEM) were developed and their performance was compared with that of an MFC loaded by 510 Ω external resistance. A copper removal of 97.8 ± 4.5% and 98.3 ± 4.8% was achieved for 10 days by MES with PEM and MFC, respectively, while by using MES without PEM a removal of over 95% was obtained for only 2 days. In both operation modes, Cu2O coatings were deposited on the cathodes. The highest cathodic efficiency of 61.7 ± 6.9% was achieved with the MES without PEM, while the highest copper recovery of 42.4 ± 4.9% was obtained with the MES with PEM. The regeneration of copper reached by using MES is over 10% higher than that gained by the MFC. The obtained results show the applicability of MES for water purification from copper without additional energy input.
• 2022
In this study, we demonstrate for the first time the use of the microbial electrochemical snorkel (MES) for silver recovery from aqueous solutions. For comparison, identical bioelectrochemical reactors in which the cathodes were connected through a 510 Ω load resistor (MFC) with the bio-anodes of well-acclimated sediment microbial fuel cells were operated at the same other conditions. Three different types of cathodes - silver foil, copper foil, and graphitized paper, were explored for silver recovery from AgNO3 solution. The data obtained show that the operation in MES mode is more advantageous than that in MFC mode in terms of both silver removal and recovery. The XPS analysis has proved that on the silver foil and graphitized paper cathodes the silver is recovered as Ag0 particles, while on the copper foil cathodes mixed Ag-Cu deposits are obtained due to the predominant electroless displacement of Cu by Ag+. The superiority of operation in MES mode was also confirmed by experiments performed with [Ag(S2O3)2]3- - containing solution, simulating exhausted photographic fixer. The total amount of silver was removed from the MES-catholyte for 24 hours, while during the operation in MFC mode a silver removal of 88.2±5.8 % was reached.
• 2025
• 2010
• 2024
• 2013
• 2023
• 2023
• 2022
• 2020
• 2019
• 2012
Microbial desalination cells (MDCs) use the electrical current generated by microbes to simultaneously treat wastewater, desalinate water, and produce bioenergy. However, current MDC systems transfer salts to the treated wastewater and affect wastewater's beneficial use. A microbial capacitive desalination cell (MCDC) was developed to address the salt migration and pH fluctuation problems facing current MDCs and improve the efficiency of capacitive deionization. The anode and cathode chambers of the MCDC were separated from the middle desalination chamber by two specially designed membrane assemblies, which consisted of cation exchange membranes and layers of activated carbon cloth (ACC). Taking advantage of the potential generated across the microbial anode and the air-cathode, the MCDC was capable of removing 72.7 mg total dissolved solids (TDS) per gram of ACC without using any external energy. The MCDC desalination efficiency was 7 to 25 times higher than traditional capacitive deionization processes. Compared to MDC systems, where the volume of concentrate can be substantial, all of the removed ions in the MCDC were adsorbed in the ACC assembly double layer capacitors without migrating to the anolyte or catholyte, and the electrically adsorbed ions could be recovered during assembly regeneration. The two cation exchange membrane based assemblies allowed the free transfer of protons across the system and thus prevented significant pH changes observed in traditional MDCs.
• 2012
• 1995
• 2015
A mediator-type bioelectrochemical sensor was developed by using polypyrrole (PPy) immobilized ferricyanide (FC) as mediator and immobilized Pseudomonas aeruginosa (P. aeruginosa) as a biosensing film for biochemical oxygen demand (BOD) fast detection. The sensor chip consists of a three-electrode system, with Au working electrode (WE), Pt counter electrode (CE) and Pt pseudoreference electrode (RE) compactly integrated as a disposable using micro-electro-mechanism system (MEMS) technology. The FC mediator and P. Aeruginosa microorganisms have been embedded in PPy matrix on gold microelectrode surface during the electropolymerization of pyrrole monomer using electrochemical cyclic voltammetry (CV) method. This bioelectrochemical sensor responds to BOD due to yielded ferrocyanide during catalytic reduction by metabolic reactions of microorganisms. A good linear correlation with chemically determined BOD values was obtained from 5 to 100 mg/L with fast response time. The proposed sensor in this paper is significant for BOD fast detection.